Teledyne-lecroy SDA III-CompleteLinQ Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Software Teledyne-lecroy SDA III-CompleteLinQ. Teledyne LeCroy SDA III-CompleteLinQ User Manual [es] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 59
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Operator's
Manual
SDAIII-CompleteLinQ
Software
Vista de página 0
1 2 3 4 5 6 ... 58 59

Resumo do Conteúdo

Página 1 - Operator's

Operator'sManualSDAIII-CompleteLinQSoftware

Página 2

SDAIII-CompleteLinQ SoftwareSDAFramework DialogThis SDAIII-CompleteLinQ Framework dialog is the main configuration screen for all serial data analysi

Página 3 - TABLE OF CONTENTS

Operator's ManualSignal Input button - Touch to open the Signal dialog, which is used to configure settings for the activelane including the data

Página 4

SDAIII-CompleteLinQ SoftwareLaneScape Comparison ModeWhen multiple lanes are enabled for display/analysis, the oscilloscope activates LaneScape Compar

Página 5 - SDAIII-CompleteLinQ Overview

Operator's ManualDual - Two LaneScapes are shown side-by-side. Tabs for selecting lanes/frames appear above the grid inboth LaneScapes.Mosaic - A

Página 6 - Key Features

SDAIII-CompleteLinQ SoftwareAssignment of Traces to LaneScapesLaneScape mode is architected to facilitate easy comparison of SDAIII-CompleteLinQ resul

Página 7 - Required Firmware

Operator's ManualSetting Up Quick ViewFollow these steps to set up Quick View.1. If you haven't done so already, touch Analysis → Serial Dat

Página 8 - New Oscilloscopes

SDAIII-CompleteLinQ SoftwareThe minimum configuration requirement is to:l Set up a signall Set up either a Reference Clock or Clock RecoveryIf you hav

Página 9 - Accessing SDAIII-CompleteLinQ

Operator's ManualSignal InputsSet Up SignalFollow these steps to define the characteristics of the input signal to be analyzed.1. On the menu bar

Página 10 - SDAFramework Dialog

SDAIII-CompleteLinQ SoftwareSignal DialogOn the SDA Framework dialog, touch the Signal tab or the Signal Inputs button to access the Signaldialog.Lane

Página 11 - 921143 Rev A

Operator's ManualSerial Data InputsThere are several scenarios for the configuration of the SeriaData Input(s) section.If you are using a differ

Página 12 - LaneScape Comparison Mode

SDAIII-CompleteLinQ Software Operator's Manual© 2013 Teledyne LeCroy, Inc. All rights reserved.Unauthorized duplication of Teledyne LeCroy docume

Página 13 - Operator's Manual

SDAIII-CompleteLinQ Softwareor other small glitches in the signal. The default value is 500mdiv, or 1/2 a division. When the input sig-nals are proper

Página 14 - Quick View

Operator's ManualClockSet Up Clock RecoveryFollow these steps to define the clock recovery method to be used for a given input signal.1. Touch An

Página 15 - Lane Configuration Process

SDAIII-CompleteLinQ SoftwareWith each acquisition, the clock recovery algorithm determines the optimal recovered clock. Using thissetting causes stati

Página 16 - Signal Input vs. Quick View

Operator's ManualPLLTypesFC GOLDENFC Golden is the default selection and implements the golden PLL as defined in the Fibrechannel spec-ification

Página 17 - Signal Inputs

SDAIII-CompleteLinQ SoftwareThe DVI selection displays the DVIPLL dialog at the far right of the screen and follows the requirementsof the DVI (Digit

Página 18 - Signal Dialog

Operator's Manualthis relationship is fc= 2.06 fn. Settings for the Custom PLL: Touch inside the Poles field to select theorder of the PLL. The n

Página 19 - Crossing Levels

SDAIII-CompleteLinQ SoftwareClock Recovery Implementation Usinga PLLAs shown in the previous image, the initial output and the output of the digital

Página 20 - Signal Types

Operator's Manual1. Touch the Ref. Clock Input button on the SDA Framework dialog to access the Ref. Clock dialog. Ifthe Ref. Clock Input button

Página 21 - Clock Recovery Dialog

SDAIII-CompleteLinQ SoftwareEye MeasurementsEye Measurements OverviewEye diagrams are a key component of serial data analysis. They are used both quan

Página 22 - PLL Setup

Operator's ManualEye DialogThe Eye dialog is the principal tool for setting up Eye diagrams. Click the Eye Meas. button on the SDAFramework dialo

Página 23 - PLLTypes

Operator's ManualTABLE OF CONTENTSSDAIII-CompleteLinQ Overview 3Key Features 4What's New in SDAIII-CompleteLinQ 4Compatible Oscilloscope Mod

Página 24

SDAIII-CompleteLinQ Software8. Touch inside the Y field and enter a value from 0 to 100%. As you enlarge the mask's Y margin, youwiden the vertic

Página 25 - Clock Recovery Theory

Operator's ManualIsoBERfrom/to/step - Select the range of BER values for which you would like to show contours in theISOBer plot.Upsample- Incre

Página 26 - Set Up Reference Clock

SDAIII-CompleteLinQ SoftwareWhen selecting a Signal Type on the Signal tab for a serial data standard, the Mask section of the EyeMeasure. Each standa

Página 27

Operator's ManualEye Parameters DialogThe Eye Parameters right-hand dialog lets you choose which parameters you want to show on thescreen. You ca

Página 28 - Eye Measurements

SDAIII-CompleteLinQ Softwarerather than electrical signals. In the presence of inter-symbol interference and/or equalization,it may notgive reasonable

Página 29 - Set Up Eye Diagram

Operator's ManualThis measurement algorithm is best suited to eye diagrams that are rendered from optical rather thanelectrical signals. In the p

Página 30

SDAIII-CompleteLinQ SoftwareEye Analysis TheoryEye diagrams are persistence maps, where each pixel in the map takes on a color that indicates howfrequ

Página 31 - Mask Testing

Operator's ManualEye PatternsSDAIII-CompleteLinQmeasures eye patterns without using a trigger. This is done using the software clockrecovery (dis

Página 32 - Mask Margin

SDAIII-CompleteLinQ SoftwareJitter MeasurementsSet Up Jitter MeasurementsTouch the Setup Jitter Measurements button on the Serial Data Analysis II dia

Página 33 - Eye Measurement Parameters

Operator's ManualPattern AnalysisA progress bar and helper information is displayed under the Pattern Analysis button, and an LEDaboveto inform

Página 34 - Average Power

SDAIII-CompleteLinQ SoftwareJitter Parameters 47Vertical Noise Measurements 48Vertical Noise Measurements Overview 48Noise Filter 49Noise Pattern Anal

Página 35 - Mask Out

SDAIII-CompleteLinQ SoftwareJitter HistogramUpdate the TIE histogram and the Rj+BUj histogram with the values in the TIETrend and the RjBUjTrend,respe

Página 36 - Eye Analysis Theory

Operator's ManualJitter FilterYou can optionally apply either a low-, high-, or band-pass filter to the TIE-vs.-time data measured on thesignal u

Página 37 - Eye Patterns

SDAIII-CompleteLinQ SoftwarePattern Analysis DialogThe Pattern Analysis dialog provides controls used to set how the serial data analysis measures and

Página 38 - Jitter Measurements

Operator's ManualRepeating Pattern - Mark this checkbox to use the repeating pattern mode. Unmark it to use non-repeat-ing pattern mode.REPEATING

Página 39 - Jitter Spectrum

SDAIII-CompleteLinQ SoftwareJitter TrackThis dialog is used to display any of the three available jitter track results. If the box is checked, the Tra

Página 40 - Jitter Parameters

Operator's ManualShow PjInv.FFT - Checking this box displays the Pj Inverse FFT. This plot is the inverse FFT of only thepoints of the RjBUjSpect

Página 41 - Jitter Pattern Analysis

SDAIII-CompleteLinQ SoftwareRjBUj SpectrumWhen displaying the RjBUj Spectrum, the spectral analysis takes the FFT of the RjBUjTrack (DDjremoved). Note

Página 42 - Pattern Analysis Dialog

Operator's ManualPeak ThresholdPeak Threshold view enables you to know what peaks are viewed as Pj for downstream analysis.Spectrum with Threshol

Página 43 - Pattern Dialog

SDAIII-CompleteLinQ SoftwareJitter Histogram AnalysisTwo jitter histograms can be viewed in SDAIII-CompleteLinQ, the TIE histogram, which contains all

Página 44

Operator's ManualJitter ParametersTouch the Jitter Parameters button on the Jitter Measurement dialog to display the JitterParametersdialog and s

Página 45

Operator's ManualSDAIII-CompleteLinQ OverviewThe SDAIII-CompleteLinQ Serial Data Analysis package introduced with firmware version 6.9.0.x provid

Página 46 - RjBUj Spectrum

SDAIII-CompleteLinQ SoftwareVertical Noise MeasurementsVertical Noise Measurements OverviewVertical noise measurement capabilities are part of the SDA

Página 47 - Pj Inv. FFT

Operator's ManualNOTE: if the Noise Meas button is greyed out, then the oscilloscope has not been outfitted with XTALKoption code, which is enabl

Página 48 - Jitter Histogram Analysis

SDAIII-CompleteLinQ SoftwareNoise Pattern AnalysisThe Pattern Analysis dialog provides controls used to set how the noise analysis algorithm determine

Página 49

Operator's ManualxN - Identified patterns are multiplied by xN times to form the pattern used for the Repeating Patternmethod. For example, if th

Página 50 - Vertical Noise Measurements

SDAIII-CompleteLinQ SoftwareNoise SpectrumOn the Noise Measurement dialog, touch the Noise Spectrum button to display the Noise Spectrumdialog at the

Página 51 - Noise Filter

Operator's Manualpopulations or normalizations. Shown with the Q-scale transform is the best straight line fit (the thinwhite line).Noise Parame

Página 52 - Noise Pattern Analysis

SDAIII-CompleteLinQ Software2. Subtracting the noiseless version of the pattern (iterated as necessary), from the original waveformreturns a noise wav

Página 53 - Noise Track

Operator's ManualCrosstalk MeasurementsCrosstalk AnalysisCrosstalk Analysis is part of the SDAIII-Crosstalk, SDAIII-CrossLinQ and and SDAII-Compl

Página 54 - Noise Histogram Analysis

SDAIII-CompleteLinQ SoftwareDialog Elementsfrom: Smallest BER value, which will correspond to the BER value of the contours furthest from the signaltr

Página 56

SDAIII-CompleteLinQ SoftwareKey Featuresl Simultaneous analysis of up-to-four lanes of data (requires one of the LinQ options).l Two overall types of

Página 57 - Crosstalk Measurements

Operator's Manualtrack, noise spectrum, histogram and Q-fit, and noise measurements broken down into Tn (total noise),Rn (random noise) and Dn (d

Página 58 - Dialog Elements

SDAIII-CompleteLinQ SoftwareGetting Started with SDAIII-CompleteLinQHow to Order SDAIII-CompleteLinQ CapabilitiesSDAIII-CompleteLinQcapabilities can

Página 59

Operator's ManualAccessing SDAIII-CompleteLinQAccess the SDAIII-CompleteLinQ by choosing Analysis>Serial Data to display the SDA Framework dia

Comentários a estes Manuais

Sem comentários